good morning it's me . Thanks for 
tuning in another great informative educational   and hopefully entertaining video. 
Hopefully i can make you guys smile.   Anyway it was a matter of time ladies and 
gentlemen a matter of time a matter of time before we go on our first well actually technically 
second combi .   Yep! Oh that's right ladies and gentlemen the apple does not fall fall far 
from the tree if it's a well   you're destined and determined to 
have problems. Typical wall hunk junk   so a little bit of background information 
this NFC i think it's a 175 replaced a ch   210 or 240 about two years ago as a warranty 
replacement we ripped off ripped off the   entire system off the wall relocated the 
system and piped in everything brand new let's go see what's going on ladies and 
gentlemen let's go see what's going on   wow love what we did with the 
place and the garage is gone   you haven't been here since then no oh wow 
wow and there's problems with the navy yeah   but it wasn't working and now 
it's like working on truthful all right let's go see well the 
rentals really came out nice   yeah all right that's right because you you had 
um someone else had someone else come through   yeah they turned out nice i bought them from 
someone else that never installed them so the   only thing i would have done different 
yeah it's exactly the same but just do   every single one like like six or seven you 
know so that they're bigger because like   these guys are a little skinnier but longer 
yeah i might like just swap out for like it's   nice though wow this place came uh yeah drop this 
bathroom here oh yeah put a little pump in here when did the problem start um so i was 
i was in puerto rico for the winter   um this nice this new code that's warm there 
yeah it was super nice now i'm like freezing the flame lost thing has been since we installed 
it but it's always been something where like a   couple times i'm here and it's like maybe there's 
i think it might be the vent outside the way it's   positioned i don't think so okay because it goes 
out and i'd have to like text someone to like come   over and like just unplug it and plug it back in 
with the flight what's the error flame loss flame   loss i don't know the error it just always says 
like flame loss error history so we're getting   0 60 that's the new one i think right which 
has occurred probably the last like and then 12   months yeah 0 60 and 12.

Navien NFC-175 Error 060-01 Abnormal Dual Venturi - How To Diagnose And Replace Step By Step

Navien NFC-175 Error 060-01 Abnormal Dual Venturi - How To Diagnose And Replace Step By Step

Navien NFC-175 Error 060-01 Abnormal Dual Venturi - How To Diagnose And Replace Step By Step

Navien NFC-175 Error 060-01 Abnormal Dual Venturi - How To Diagnose And Replace Step By Step

All right let's give 
them a call all right so let's just review here fresh air and with martian 
air questionnaire goes out three zones one is radiant 
as you can see navi clean tits filter on the incoming domestic water all right let's go see the venting all right they're gonna [ __ ] complain that i don't 
have 12 inches of vertical separation tech support technician on 
site calling for an nfc 175. all right so i got navy on the 
phone i kind of like had to like   basically take over the conversation is like well 
if the error is not occurring right now you know   not much we can do i'm like yo bro he's got this 
error message like 10 times over the past weekend   it's cause it's not doing it now like let's fix 
this problem while i'm here it's okay then oh   you need to replace the dual venturi i'm like 
okay so send me one and he didn't even bother   checking that it was a warranty exchange he 
goes okay no problem game is my address boom   done easy peasy i don't stock the nf's and the 
combi parts the fire two parts at all   because they didn't make a part kit 
for it yet when i was uh still in nss   but very easy you know i made sure the 
connection inside was secure which it was   and um that was it called them up they said 
okay well overnight you have a new inventory   so we'll be back on wednesday today 
is monday to put it in all right   thanks for watching stay tuned for 
part two which is coming up right now i'm back all right let's replace the dual inventory 
i also have uh a 45 we're gonna put on the   exhaust and we'll see if that has any 
a change on the uh the light switcher there you go okay has it errored 
out since i was here the other day   actually not it's that funny thing 
right when like you finally start to   okay you want to see that it doesn't 
happen i hear you all right all right   cool all right let's pop that out you got 
it okay here's our nfc 175 let's take our clips out one two get the ones 
on top and we'll swap out this   dual insert all right let's 
start with killing power okay our dual venturi let's open up that box i 
have a little knife the gerber knife got that   from the youtube subscriber nice and we have a 
lot of nice youtube subscribers they send gifts   love letters thank you cards gifts one guy even 
sent me some silver and gold bullion coins i mean   that's coins so there's a dual venturi and that 
is where is that thing where could this thing be i   think it's that is that that it or is it hmm oh no 
it's this there it is it's that piece right there okay let's turn off the gas what the [ __ ] some pump all right so ladies and gentlemen 
how to replace a dual venturi on an avian   combi nfc 175's 200's are the 
same all right there it is built in 2019 look how how much precision on the installation 
is here right look at that even i even zip tied   the wiring for the zones isn't that so nice and 
pretty that's nice that's that's tits by the way   that really is really nice i guess i could have 
done a little bit cleaner job with the low voltage   zone three you know i didn't 
this was i think mike did this but whatever okay the gas is off and we 
have to let's remove these four screws all right let's disconnect the wire which says 
venturi on it okay now we have this horn looking   thing which is attached to there and we have one 
two three four four screws holding the venturi   to the blower all right we're gonna remove those 
four screws two on top two in the bottom holding   the blower to the top of the heat exchanger 
and then we'll pull out the entire assembly let's oh more all right we got okay let's put that on the floor   and let's take off the inventory so we're 
going to keep the orientation the same so   we don't get anything confused here right 
let's take off that screw and that screw okay now there's a couple things we're gonna have   to do here but let's start by 
taking out those four screws separating the venturi from the blower motor okay let's take the new venturi now that one's   has a gasket so let's take that 
red gasket and put it on there   that little groove all right make sure it sits 
in there nice good now let's put the new venturi   back onto there is that the same way it was on 
before yes okay good let's put the screws back in now that they're all hand tight let's give 
them make some make sure they're nice and snug okay now here's that pro side profile 
and take a look at that one   grab that one no that all right 
now what do you see different okay what else you see different look at this and look at that 
what do you see different   no no no no um it was upside down 
okay what do you see different now this plate yes so that's the plate 
i believe is for different fuels   and that should be the one for natural gas 
and for propane lp will be a different one   so let's take that out and remember the exact 
orientation it was in i could tell you this   though it looks different already though just 
the whole thing yeah it does look different yeah i mean this is blank and this has numbers 
in it yeah let's see take the other screw out   it could be just my imagination or   depth perceptions playing a game on me all 
right let's take that rubber gasket out   all right let's take that little piece 
out and put that back in the way it was okay let's put those screws back 
in and then put the gasket back in so nice and tight okay let's put the gasket back in   okay i'm surprised they didn't give us new gaskets 
but this is what they gave us all right all right   so here's the below inventory assembly now we have 
that piece to go back on here two screws hold this   air intake assembly loopy kind of reminds me of a 
pigtail on the steam obviously much bigger and as you guys could see we're using 
the long navy and phillips screwdriver   that they were so nice to give me many years ago 
as part of their promotional package kind of like   their shirts and their hats all right good old 
navy and screwdriver see that's an avian that   says navian as well so does that but they want to 
sue me in arbitration for using their trademark   and defaming their character here we have 
it a little over two-year-old nfc 175   that already are replacing a pardon the dual 
venturi what a shame they just don't make things   like they used to actually that's just south 
korea america that's just navy and by the way   all right that's nice and secure okay all right 
i'm holding this obviously it's like a easier   if it's a two-person job i'm holding the blower 
against the top of the heat exchanger i already   put back on oh did it fall off it did it's fine we 
put it back on let's get a couple screws in there   and then hook up the gas to the 
inventory all right those four screws   from the blower to the top of 
the heat exchanger are secure   now we're hooking up the four screws from top 
of the gas valve to the side of the venturi   and make sure that they're going properly 
and we don't cross thread anything i've   already hooked up the power to the blower right 
there and the only thing left to do is venturi   and then the little breather tube on the 
bottom of this air inlet thingamajiggy so great okay venturi power is 
connected blowers connected breather   i guess line yeah that goes into a pressure switch 
pressure tubing pressure switch is connected   everything is good nice solid and tight the 
only thing left to do now is plug it back in looks like we have space three is calling but i don't have anything illuminated here nothing's lit up this is zone three all right oh there's a little delay look at that okay very nice we need to turn the gas back on   that would help right because it 
looks like we're going to error out on there we go we have ignition 
flame icon has appeared zone three domestic hot water is off we have 15.5 
psi pressure system and right now 136 degrees   i'm just going to show you guys one 
quick thing that i like to do with   especially condensing systems a condensing 
system thrives on lower set point temperature   is this thing manufactured to provide 
spacing at 180 degrees absolutely will   it condense at 100 degrees absolutely not 
all right so one of the things i like to do   on all of the condensing systems we install is 
that i set my space heating temperature right   to 165 degrees the lower this number and that's if 
we need it 180 degrees so like right here as you   can tell you know we have the rental baseboards 
very nice beautiful baseboards there right   but they're designed for maximum output at 180 
degrees of spacing temperature we can sacrifice   temperature and btus but also make the machine 
thrive is it going to condense at 165 degrees   absolutely is it going to condense as much as it 
would if it was set for 140 degrees absolutely not   my own navian nfb 200 i personally set for 145 
degrees now granted most of the heat in my home   is in floor hydronic radiance i do have a couple 
zones of convectors and fintu baseboard which   would like to see 180 degrees but on the average 
winter day the is condensing generally   two to three gallons of condensate per day and it 
thrives and the more you make a machine like this   thrive the intention is to last longer would 
that have would a lower temperature prevented   this from not dying no because as you saw in the 
earlier part of this video the space heating was   set for 123 degrees and he was actually a 
little bit cold in his house this winter   but now it's at 160 and we have 
that running let's go put on the   45 on outside well we don't got any vertical 
separation but like we got about six feet of   horizontal but navy would still deny a 
warranty if they saw this so let's take out damn here try to get this thing off oh we got 
it see we got it so there's our little 45   the homeowner was saying that he feels that 
on very strong wind days the wind's coming   across the bay and blowing into here and 
it's causing ignition uh ignite flame loss   maybe yes maybe no but nonetheless i put a 45 
on here and uh now we're good by the way i have   a split ring hanger here a piece of threaded rod 
on the plate i guess this was a galvanized plate   well chinese or carisium south korean easium say 
spiroven by the way this is uv rated even though   it's not black all the new central therms are uv 
rated and here's our fresh air and this is some   kind of vent or maybe the pump all right guys 
i hope you enjoyed this educational video on   how to diagnose an avian fire tube combi and also 
how to replace a venturi now i know that you know   the folks over at navy and they don't really have 
the in-class in-person training anymore but if you   enjoyed this video and you found it helpful 
and educational i would really appreciate if   you consider subscribing there's absolutely no 
cost or obligation and the more subscribers we   have the more motivated i've become to create 
more educational videos such as this one and   as you guys know my long-term long-term viewers of 
the channel i do a lot of work with navian and yes   in my opinion they're garbage especially the water 
tube models because they leak combustion gases at   the top of the heat exchange which i've proved 
many times but nafion says it's okay nonetheless   blah blah blah blah if you like this video 
thumbs up share with your friends and co-workers   and most importantly subscribe 
thank you so much be well god bless you

Navien NFC-175 Error 060-01 Abnormal Dual Venturi - How To Diagnose And Replace Step By Step

As found on YouTube

Navien NFC-175 Error 060-01 Abnormal Dual Venturi - How To Diagnose And Replace Step By Step

Free Coupon Download; Up To 80% OFF

No response yet on Navien NFC-175 Error 060-01 Abnormal Dual Venturi – How to Diagnose and Replace Step by Step

Leave a comment

will not be published

Touch to Call!
Call Us
%d bloggers like this: